User Manual
176 i Series / iX Series
Table ADC14:
Test No.
Section
Subject
Test Limits
Comment
File Ref.
16.6.1
Normal Operating Conditions (dc)
16.6.1.1b
Voltage (Average Value dc)
11.0V to 15.2V
Apply for 30 mins each test
EADC14_VAVG
16.6.1
Emergency Operating Conditions (dc)
16.6.1.1b(3)
Voltage (Average Value dc)
9.0V
Apply for 30 mins each test
EADC14_VAVGEMER
16.6.1
Normal Operating Conditions (dc)
16.6.1.2
1
Ripple Voltage (dc)
Vp-p = 0.3V to .8V, Freq = 10Hz to 200Hz
Figure 18-2
EADC14_VRIP
16.6.1.3b
Momentary Power Interruptions (dc)
Table 16-3
Equipment with Digital Circuits
EADC14_PINTB
16.6.1.3c
Momentary Power Interruptions (dc)
Other Equipment
EADC14_PINTC
16.6.1.4
Normal Transients (dc)
16.6.1.4b - Normal Voltage Surge (dc)
23.5V to 8.5V
EADC14_NVSUR
16.6.2
Abnormal Operating Conditions (dc)
16.6.2.1
Voltage Steady State (dc)
10.3V to 16.1V
Apply for 5 mins each test
EADC14_VABN
16.6.2.3
Momentary Undervoltage (dc)
6V
Apply for 7 seconds each test
EADC14_VUND
16.6.2.4
Abnormal Transients (ac)
16.6.2.4c - Abnormal Voltage Surge
23.2V
Figure 16-4 - apply at 10 sec
intervals
EADC14_AVSUR
1
For more comprehensive DC Ripple tests, refer to section 9.1.2.10.