7. Service
7.1 Cleaning
The exterior of the power source may be cleaned with a cloth dampened with a mild detergent
and wrung out. Disconnect mains power to the source before cleaning. Do not spray water or
other cleaning agents directly on the power source.
7.2 General
This section describes the suggested maintenance and troubleshooting procedures. The
troubleshooting procedure is divided into two sections. The first section deals with basic
operation and connection of the equipment. The second section requires opening the unit and
using the LED indicators and a simple multimeter to troubleshoot the unit down to the module
level. Only a qualified electronic technician should attempt this level troubleshooting.
7.3 Basic operation
Table 7-1: Basic Symptoms
Poor Output Voltage Regulation
Unit Shuts Down After 1-2 Seconds
No Output and no lights on front panel
No output but “power on” LED on front panel is lit.
7.3.1 Excessive Output Voltage
External sense not connected
Connect the external sense to the AC
power outlet TB2.
7.3.2 Poor Output Voltage Regulation
Unit is programmed to wrong voltage
range.
Select correct voltage range.
Input line has fallen below spec. limit.
7.3.3 Overload Light is On
Unit is switched to high voltage range.
Select correct voltage range.