Parameter Instance #9 (Setpoint 3 on position)
Attribute ID Access Rule Name Data Type Value
1 Get/Set Parameter Value USINT Setpoint 3 on position
2 Get Link Path Size USINT 0x06
3 Get Link Path ARRAY “0x20 0x65 0x24 0x03 0x30 0x02”
4 Get Descriptor WORD 0x0000
5 Get Data Type USINT 0x02
6 Get Data Size USINT 0x02
Parameter Instance #10 (Setpoint 3 off position)
Attribute ID Access Rule Name Data Type Value
1 Get/Set Parameter Value USINT Setpoint 3 off position
2 Get Link Path Size USINT 0x06
3 Get Link Path ARRAY “0x20 0x65 0x24 0x03 0x30 0x03”
4 Get Descriptor WORD 0x0000
5 Get Data Type USINT 0x02
6 Get Data Size USINT 0x02
Parameter Instance #11 (Setpoint 4 on position)
Attribute ID Access Rule Name Data Type Value
1 Get/Set Parameter Value USINT Setpoint 4 on position
2 Get Link Path Size USINT 0x06
3 Get Link Path ARRAY “0x20 0x65 0x24 0x04 0x30 0x02”
4 Get Descriptor WORD 0x0000
5 Get Data Type USINT 0x02
6 Get Data Size USINT 0x02
Parameter Instance #12 (Setpoint 4 off position)
Attribute ID Access Rule Name Data Type Value
1 Get/Set Parameter Value USINT Setpoint 4 off position
2 Get Link Path Size USINT 0x06
3 Get Link Path ARRAY “0x20 0x65 0x24 0x04 0x30 0x03”
4 Get Descriptor WORD 0x0000
5 Get Data Type USINT 0x02
6 Get Data Size USINT 0x02