Programming Manual Lx \ Ls Series II
90
This command sets the width of a transient output pulse. The command parameters are model-
dependent.
Command Syntax [SOURce:]PULSe:WIDTh<NRf+>
Parameters 3-phase models: 0 to 1.07533E6 | MINimum | MAXimum
1-phase models: 0 to 4.30133E5 | MINimum | MAXimum
Unit s (seconds)
*RST Value 0.01667 (equals the period of a single 60 Hz cycle)
Examples PULS:WIDT 0.001 PULS:WIDT MIN
Query Syntax [SOURce:]PULSe:WIDTh?
Returned Parameters <NR3>
Related Commands PULS:COUN PULS:DCYC PULS:HOLD PULS:PER