PULSe:WIDTh
This command sets the width of a transient output pulse.The command parameters are
model-dependent.
Command Syntax [SOURce:]PULSe:WIDTh<NRf+>
Parameters 1 msecs to 90,000 secs |MINimum|MAXimum
Unit S (seconds)
*RST Value 0.5 secs
Examples PULS:WIDT 0.001PULS:WIDT MIN
Query Syntax [SOURce:]PULSe:WIDTh?
Returned Parameters <NR2>
Related Commands PULS:COUN PULS:DCYC PULS:PER